This case study highlights a common issue in ventilation systems:
systems that appear to be working but are not effectively controlling airborne contaminants within enclosed spaces.
LEV Tec Solutions carried out a Ventilation Design Review to assess whether the existing system could achieve effective air movement and contaminant removal.
The property utilised an existing extract ventilation system serving an enclosed internal space.
While the system was operational, the client reported:
Air feeling stagnant during use
Lingering airborne contaminants after use
Concerns regarding overall air quality and effectiveness
This raised concerns that the ventilation system was not effectively removing airborne contaminants or maintaining adequate airflow.
During assessment, LEV Tec Solutions identified:
Limited air movement within the occupied zone
Ineffective airflow path through the space
Extraction not achieving sufficient capture and removal
System performance restricted despite being operational
Air movement was present, but not at a level sufficient to control contaminants effectively.
Undersized ductwork restricting airflow capacity
System not designed to overcome resistance within the duct route
Inefficient extract positioning relative to airflow patterns
Insufficient make-up air to support system performance
Without effective ventilation:
Airborne contaminants can accumulate within the space
Air quality deteriorates during and after use
Contaminants may migrate to adjacent areas
Under COSHH principles, exposure must be effectively controlled — not assumed based on system operation alone.
LEV Tec Solutions provided a clear, performance-led design specification, including:
Upgrade to correctly sized ductwork to improve airflow
Improved extract positioning to enhance capture
Selection of a centrifugal fan suitable for system resistance
Optimisation of airflow path through the space
Improved make-up air provision to support system performance
Following implementation of the design principles:
Air movement within the space is significantly improved
More effective removal of airborne contaminants
Reduced stagnation and improved air quality
Better overall performance aligned with intended system function
Ventilation systems do not guarantee effective control simply by operating.
If duct sizing, airflow design, and system performance are not correct, airborne contaminants will remain and air quality will be compromised.
Most systems are assumed to be working.
Few are actually designed to perform.
If your ventilation system is running but you’re unsure whether it is effectively controlling airborne contaminants, a structured performance review can identify deficiencies before they become compliance issues.
LEV Tec Solutions provides independent ventilation performance assessments aligned with COSHH Regulation 9 and HSG258 guidance.
0800 046 1607
enquiries@levtecsolutions.com

Independent LEV Testing Specialists No Installation Sales
LEV Tec Solutions, 71-75 Shelton Street, Covent Garden, London. WC2H 9JQ
| Company VAT No: 497525247 | ICO Registration Number: ZC192661 | Cookie Policy | Privacy Policy