Overview
This case study highlights a common issue in UK workshops:
dust escaping from enclosed CNC machines despite extraction being installed.
LEV Tec Solutions carried out an Air Quality & LEV Performance Review to assess whether the system was effectively controlling exposure to wood dust.
The Problem: CNC Dust Extraction Not Controlling Exposure
The woodworking facility operated enclosed CNC routers connected to a central dust extraction system.
While the system appeared functional, the client reported:
On-Site Findings: Why Dust Was Escaping
During live operation, LEV Tec Solutions observed:
Root Causes Identified
Poor enclosure sealing allowing dust leakage
Insufficient airflow to maintain negative pressure within the enclosure
Loss of containment during operation and post-cycle access
The Risk: Exposure to Respirable Wood Dust
The escaping dust included fine respirable particles, which pose serious health risks, including:
The Solution: Improving CNC Dust Extraction Performance
LEV Tec Solutions provided clear, practical recommendations:
The Result: Improved Dust Control
After implementing recommendations:
Key Takeaway
CNC dust extraction systems do not guarantee effective control. If airflow and enclosure integrity are not correct, fine wood dust will escape and exposure will occur.